Facilities

Image

 

Capable for the determination of C, H, N and S elements 

 

Image

 

  1. Platinum-ATR-accessory
  2. Measurement range (in vacuum condition): 80 to 4000 cm-1

 

Image

 

  1. Wavelength range: 200 to 1010 nm
  2. Temperature range: 10掳C to 90掳C (Solution)
  3. Solid state attachment

Image

 

  1. With Linkam LTS420 Heating and Cooling Stage
  2. Temperature range: -196 to 420掳C
  3. PointGrey Grasshopper 5 MP Color Digital Camera 

 

 

Image

 

  1. Liquid nitrogen cooling system
  2. Temperature range: -170 to 200 掳C

Image

 

  1. Simultaneous analysis of TG with DTA and DSC (mW) modes
  2. Temperature range: 25 to 900 掳C 

 

 

Image

 

  1. Wavelength range: 200 to 1010 nm
  2. Temperature range: 10掳C to 90掳C (Solution)
  3. OptistatDN2 (Solid State Analysis)
  4. Temperature range: -170掳C to 25掳C 

Image

 

  1. SmartVacPrep
  2. Cryostat (25 to 300K) 

 

Image

 

  1. Frequency: 5 - 30 Hz (300 - 1800 min-1)
  2. Grinding jar: adapter for 6 x 2 ml tubes and 5 ml stainless steel jar
  3. Operating temperature: ambient RT or -196掳C 

Image

 

  1. Max power: 850 W
  2. Max. IR temperature: 300 掳C
  3. Max. operation pressure 30 bar
  4. With integrated camera and auto-sampler 

 

 

Image

 

  1. Nuclei ranging from 15N to 31P and 19F with 1H decoupling
  2. Temperature range: -150 to 150掳C.
  3. Equipped with Magic Angle Spinning (MAS) probes for solid samples 

 

Image

 

High intensity dual microfocus PhotonJet-S X-ray sources (Mo/Cu wavelength) 

 

 

Image

 

  1. Anton Paar TTK 600 low temperature attachment
  2. Temperature range: -190 to 600掳C (vacuum) 

Image

 

  1. Room temperature measurement
  2. Rapid analysis 

 

Class II Biological Safety Cabinet (FMLS Facilities)

Image

(FMLS Facilities)

Image

 

Provide optimal growing conditions for cell cultures

 

LMO / GMO Freezer  (FMLS Facilities)

Image

 

  1. Temperature : -80掳C
  2. For the storage of LMO / GMO samples 

Cryogenic Storage System (FMLS Facilities)

Image

 

  1. Temperature : -196掳C to -210掳C
  2. Long term storage of biological samples

 

Fluorescence Microscope (FMLS Facilities)

Image

 

  1. Nikon Eclipse Ti
  2. 4 - colours imaging

HPLC (FMLS Facilities)

Image

 

 

BD FACSCelesta鈩� Flow Cytometer (SUMC Facilities)

Image

 

  1. Multiple fluorochrome system
  2. For cell analysis, assay development, verification, and identification of cellular populations of interest

Dolomite Fluidics Equipment (SUMC Facilities)

 

Image

 

Used for a wide range of applications, including drug encapsulation, droplet manufacture and nanoparticle generation

 

Real-Time PCR Cycler (DMS Facilities)

Image

 

  1. QIAGEN's Rotor-Gene Q
  2. Centrifugal rotary design

Image

 

cellenONE庐 is an all-in-one platform combining high-accuracy single cell isolation and high-precision pico to nanoliter reagent dispensing.

  1. Image-based single-cell sorting and isolation
  2. Cell line development with excellent clonal outgrowth
  3. Miniaturized end-to-end single-cell sample preparation workflows